2. APPLIANCE DATA
2.1 General information.
Under no circumstances is this fire to be converted to LPG. An LPG conversion kit
does
not
exist for this gas fire.
The appliance information label is located on the base of the fire underneath the
burner module.
2.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below:
Model
Efficiency % (Gross)
961 80
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The conversion of
net
efficiency to
gross
was achieved by multiplying the net
efficiency by the following conversion factor from Table E3 of SAP 2005, rounding
down to the nearest whole number.
INSTALLER GUIDE
Page 8
©
Baxi Heating U.K. Limited 2010.
Gas
Natural (G20)
Inlet Pressure
20mbar
Input - Max. (Gross)
5.00kW (17,060 Btu/h)
Input - Min. (Gross)
2.5kW (8,530 Btu/h)
Inlet Test Pressure (Cold)
20.0 ± 1.0mbar (8.0 ± 0.4in w.g.)
Gas Connection
8mm pipe
Burner Injector
Cat 82 - 065
Pilot & Atmosphere Sensing Device
Copreci Ref. O.D.S 21500/166
Ignition
Electronic (Battery 9V PP3)
Aeration Setting
See section 16.1