INSTALLER GUIDE
Page 16
2.
The flue must conform to BS 5440: Part 1 in design and installation.
The flue, measured from the bottom of the fireplace opening to the bottom of the
terminal, shall be not less than 3m in actual vertical height. When calculated in
accordance with BS 5440: Part 1 Annex A, the minimum
equivalent
height of the flue
shall be 2.0m of 125mm dia. flue pipe.
3.
The flue must not be used for any other appliance or application.
4
.
Proprietary terminals must comply with BS 715 or BS 1289. Any terminal or
termination must be positioned in accordance with BS 5440 Part 1 to ensure that the
products of combustion can be safely dispersed into the outside atmosphere. Where
the appliance is connected to an unlined brick chimney it is generally unnecessary for
the chimney pot to be replaced or for a terminal to be fitted unless the flue has a
diameter smaller than 170mm.
4. PACK CONTENTS
The items required for this appliance are packed in sections.
Section 1 - Fire unit contains:
1
Burner and convection box unit.
1
Burner tray trim (Supplied in separate pack).
1
Outlet baffle for the convected air outlet.
2
Tapping Screws for outlet baffle.
1
Nut and olive for 8mm inlet pipe.
1
‘T’ connector and pressure test point.
1
Flue restrictor.
3
Tapping Screws (For flue restrictor).
2
Small “U” seals (For convection box side flanges).
2
Strips of floor sealing tape.
6
Fibre / wooden plugs.
4
Woodscrews.
2
Fire retaining cables.
2
Cable clamps.
4
Eyebolts.
1
Rubber grommet (For rear of convector box).
2
Machine screws (For fascia hanging).
2
Washers for fascia hanging.
1
PP3 Battery.
1
Smoke match tube.
2
Fireback spacing brackets.
4
Tapping Screws (For fireback spacing brackets).
1
Length of self adhesive foam seal.
1
Literature pack (Not shown).
1
Ceramic fuel effect set (Not shown).
©
Baxi Heating U.K. Limited 2010.