Parameter
82
V-Controller (BUS 6 VC)
5.03047.01
Baumüller Nürnberg Electronic GmbH & Co. KG
Parameter overview
Parameter description
P382
DI
state
This parameter indicates the state of input programming.
parameter
Name
Range
min. ... max.
Unit
Display
only
P382
DI
state
0000 ... FFFF
!
P370
DI
1 target Pxxx
0 ... 700
P371
DI
1 bit selection
0000 ... FFFF
P372
DI
1 LOW pattern
0000 ... FFFF
P373
DI
1 HIGH pattern
0000 ... FFFF
P374
DI
2 target Pxxx
0 ... 700
P375
DI
2 bit selection
0000 ... FFFF
P376
DI
2 LOW pattern
0000 ... FFFF
P377
DI
2 HIGH pattern
0000 ... FFFF
P378
DI
3 target Pxxx
0 ... 700
P379
DI
3 bit selection
0000 ... FFFF
P380
DI
3 LOW pattern
0000 ... FFFF
P381
DI
3 HIGH pattern
0000 ... FFFF
P342
DI
4 target Pxxx
0 ... 700
P343
DI
4 bit selection
0000 ... FFFF
P344
DI
4 LOW pattern
0000 ... FFFF
P345
DI
4 HIGH pattern
0000 ... FFFF
Bit no.
Meaning
0
1: input 1 completely programmed
1
1: input 2 completely programmed
2
1: input 3 completely programmed
3
1: input 4 completely programmed
4 ... 7
reserved
8
actual state input 1 (X26:15)
9
actual state input 2 (X26:16)
10
actual state input 3 (X26:17)
11
actual state input 4 (X26:18)
12 ... 13
reserved
14
actual state rapid halt input (X26:19)
15
actual state pulse / controller enabling (X26:14)
Summary of Contents for BUS 6 VC
Page 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Page 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Page 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 109: ......