Technical Data
10
V-Controller (BUS 6 VC)
5.03047.01
Baumüller Nürnberg Electronic GmbH & Co. KG
2.2
Electrical Data
Power Consumption
Accuracy of whole system
Calculation accuracy 16 bit
Sampling rate of whole system
62,5 µs
2 analog inputs
voltage range
type
input resistance
resolution
-10 V ... +10 V
differential input
ca. 40 k
Ω
12 bit
5 potential free inputs
low level
high level
input resistance
0 V ... +7.5 V
+13 V ... +30 V
2,5 mA
2 analog outputs
voltage range
maximum output current
resolution
-10 V ... +10 V
1 mA
12 bit
1 relay output
maximum contact load
maximum potential against electronic
ground
24 V DC / 1 A
50 V
3 potential free outputs
joint supply voltage
joint ground
output current per output
+ 24 V / 150 mA
ground of 24 V external
50 mA
Interfaces
RS232 service interface
+5 V
1,2 A
+8 V
10 mA
+15 V
50 mA
-15 V
50 mA
Summary of Contents for BUS 6 VC
Page 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Page 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Page 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 109: ......