Parameter
V-Controller (BUS 6 VC)
47
Baumüller Nürnberg Electronic GmbH & Co. KG
5.03047.01
7.7
Drive Manager (Enable the Controller)
Function
The drive manager administrates the essential system resources of the drive. These include among
others complete unit control in various modes, switching between the different modes, the management
of all communication interfaces, error treatment etc.
Parameter overview
Parameter
Name
Range
min. ... max.
Unit
Display
only
P120
M
control word
0000 ... FFFF
P121
M
state word
0000 ... FFFF
!
P122
M
set operation mode
-6 ... 6
P123
M
actual operation mode
-6 ... 6
!
P124
M
error code
0000 ... FFFF
!
P125
M
error index
0 ... 31
!
P136
M
mode
0000 ... 0007
P126
M
communication source
0000 ... 000F
P127
M
communication monitoring
0000 ... 000F
P128
M
monitoring time
0 ... 60 000
ms
P137
M
state 1
0000 ... FFFF
!