Parameter
V-Controller (BUS 6 VC)
83
Baumüller Nürnberg Electronic GmbH & Co. KG
5.03047.01
P370
DI
1 target Pxxx
P374
DI
2 target Pxxx
P378
DI
3 target Pxxx
P342
DI
4 target Pxxx
This parameter indicates the parameter number of the target parameter for input 1 till 4.
P371
DI
1 bit selection
P375
DI
2 bit selection
P379
DI
3 bit selection
P343
DI
4 bit selection
The bits to be altered are selected in the target parameter.
P372
DI
1 LOW pattern
P376
DI
2 LOW pattern
P380
DI
3 LOW pattern
P344
DI
4 LOW pattern
Bit pattern which is written into the selected target parameter bits when digital input is LOW.
P373
DI
1 HIGH pattern
P377
DI
2 HIGH pattern
P381
DI
3 HIGH pattern
P345
DI
4 HIGH pattern
Bit pattern which is written into the selected target parameter bits when digital input is HIGH.