R9001440/9
GRAPHICS
TCR Adjustment procedure
Date:10/02/2000
6300
19
TCR Adjustment procedure
Color Meter
Put the color meter at the center of the image.
In case of the Thoma TMF use a diaphragm to avoid overranging of the meter. In that
case make sure that the light through the diaphragm hits the center spot on the back
of the white integration sphere.
The Minolta CS1000 is used in a reflective measurement mode. Use a perfect white
projection screen. Use the manual measurement mode with an integration time of
0.2s or more.
Check the RS232 to color meter section for the correct RS232 connections to the
color meter.
Running the Program
Type TCR <return>. The program consists of the following steps.
Line-up of the
measurement apparatus
Projector
Screen
to RS232 IN
projector
Color meter
PC
to COMM 1
PC
from COMM 2
PC
Step 1: Input projector
data
TCR procedure V1.30
Step1: Input projector data
Serial port for communication with projector
1. COMM1
2. COMM2
Your choice: _
Give the following input values:
The PC COMM-port for the projector control
Give the the PC COMM-port for the projector control. According to the diagram above,
COMM2 port of the computer is connected to the RS232 IN of the projector, so type in
number 2 and press
ENTER
.