R9001440/9
GRAPHICS
Uniformity Adjustments
Date:10/02/2000
6300
17
Uniformity Correction Adjustments
F :
Restore the factory default settings on the image. Also the values on the screen
will be updated.
A :
Start the automatic adjustment procedure. Instructions will be given. WARNING:
the current uniformity compensation will be erased during this process, but can be
retrieved afterwards by typing F.
M :
Start the manual top-bottom-left-right adjustment procedure.
Q :
Quit the program
The manual top-bottom-left-right adjustment menu.
<cursors> :
Select one of the corners. The uniformity values of the selected corner
are displayed
T :
Select the top border. The values of the top left and the top right corners are
displayed.
B :
Select the bottom border. The values of the bottom left and the bottom right
corners are displayed.
L :
Select the left border. The values of the top left and the bottom left corners are
displayed.
R :
Select the right border. The values of the top right and the bottom right corners
are displayed.
C :
Select the active color. Toggle between red, green, blue and white.
+ / - :
Increase / decrease value of the selected corner / border and color.
<enter> :
Send the current grid values to the projector.
Q :
Quit the manual top-bottom-left-right adjustment menu.
Overview of Commands
The main menu:
C :
Select the active color. Toggle between red, green, blue and white.
V :
Enter a value for the selected point and color.
I :
Initialize total grid.
+ / - :
Increase / decrease value of the selected point and color.
<cursors> :
Move on the grid.
<enter> :
Send the current grid values to the projector.
R :
Read the currently active uniformity values from the projector.
O :
Open a file from the PC and show the values on the screen. The values are not
yet sent to the projector. Uniformity files have the extension *.uni, which has to be
omitted. NOTE: for the BG6300 you can load the bg6300.uni file (omit the .uni).
This file will load a average first order uniformity compensation, which is better
than no compensation at all.
S :
Save the current uniformity values on the screen to a file. Again, the extension
*.uni has to be omitted.
D :
Store the current active uniformity values in the projector to the factory default
settings. Use carefully, because there is no way to retrieve the old default values
after this.