16 _____________________________________________________________ Barco – ISIS LFC – Installation Guide
2.2.2.3
LFC install
In order to be able to use LFC, LFC should be ‘installed’ first.
The following “LFC install” procedure should be carried out with utmost
precision. Entering a wrong command may render the display unserviceable
and requires a factory return.
Items neede
d
:
•
Firmware Download Tool (FDT) software;
•
a KP/Upload cable Z3498894 or equivalent;
•
a PC.
The needed items are included in the Barco ISIS Service Kit K5030070.
The Z3498894 cable pinning is also described here below.
1.
Connect the COM port of the PC directly with the REMOTE IN (J11) PIB connector with
a 3-wire crossed KP/Upload cable Z3498894.This special cable is defined as follows.
Only pins 2, 3 and 5 are used. Pin 2 and 3 are twisted.
PC (SUBD9 – Male)
ISIS (SUBD9 – Female)
2 3
3 2
5 5
2.
Install and start on the PC the “Firmware Download Tool” and select “Barco
protocol”. Click “Next”.