10 _____________________________________________________________ Barco – ISIS LFC – Installation Guide
2.1.5
Installation of modules and cables
2.1.5.1
Boards removal
From the PIB (Panel Interface Board K5830011), cut the two wire ties holding the
yellow power cable, disconnect the said power cable (with J1) and guide it through the
hole with bushing in the board’s metal support plate. See Figure 2-5 PIB power cord
removal.
1
Wire tie V348000 to be cut
1
1
Figure 2-5 PIB power cord removal
Remove the AIB (Analog Input Board) K5830040 and the PIB (Panel Interface Board)
K5830011.
Remove the decorative dummy cover plate – if any - at the empty slot (Slot2) next to
where the AIB was mounted.
On the PIB (K5830011), replace the µprocessor board (K5830020) by a µprocessor
board (K5830021) and fix this with 2 screws B361085.
Lock 2 the screws with a threadlocker, by preference Loctite 242 (Barco ref.
V395121), and a tamperproofing coating, by preference Loctite 7400 Varnistop (Barco
ref. R395213).