2.2.3
LFC calibration
2.2.3.1
Connections
Connect a Barco Keypad to connector J10, labelled “KEYPAD”, on the rear side of the
display.
Place the Optical Sensor on the front of the display and connect it to connector J40,
labelled “OPTICAL SENSOR” on the rear side of the display.
For best results, the calibration should be done at the display’s normal operating
temperature and with an input signal with scan rate specifications as normally used.
2.2.3.2
Calibration
Using the keypad, navigate to the LFC advanced Submenu:
1.
Press the UNIF button on the keypad to go to the Administrator Menu.
Note: The administrator password is required before entering the Administrator Menu.
The password (9090) must be entered via the first line of the menu under the MISC2
button:
2.
In the Administrator Menu go to the second line of the second page and hit enter on
Input Boards to open the Input Boards Submenu.
3.
In the Input Boards Submenu hit ENTER on the third line, called LFC advanced.. to go
to the LFC advanced Submenu.
4.
Finally LFC calibration is located on the second page of this LFC advanced Submenu.
Go to this page.
LFC calibration page on the keypad:
LFC Calibration<
Start:
E
Status:
>