![background image](http://html1.mh-extra.com/html/barco/id-h250/id-h250_service-manual_3858134014.webp)
2. General information
Flat Cable Connector
•
Do not use any tools when (dis)connecting a flat cable connector, otherwise damage may occur on the mini locks.
•
Disconnect by simultaneously pulling out the 2 mini locks on both sides of the flat cable connector.
Image 2-3
Pull out the 2 mini locks on both sides of the flat cable connector
•
Do not touch the contacts of the flat cable when removing/inserting the flat cable otherwise damage may occur by oxidation of
these contacts.
Image 2-4
Do not touch the contacts of the flat cable
•
Do not bend the flat cable, otherwise internal cable damage may occur.
•
Insert the flat cable in a straight way into the flat cable connector.
Image 2-5
Insert the flat cable in a straight way
•
Connect the flat cable by simultaneously pushing the mini locks on both sides of the flat cable connector.