4.1.2
Mounting to the Bär Control EVO / the control box
1. Slide the receiver into the holder Mat. no. 200008990 until the cable of the receiver reaches the strain
relief.
2. Attach the cable to the strain relief using a cable tie.
3. Mount the Bär Control Evo / control box to the receiver holder.
4. Lay the cable from the receiver at the control box to the eBC Controller Pro bundled with the Bär
Control EVO / control box cable. If the receiver cable is too short, it must be extended using cable Mat.
no. 200007663. The connection point of the two cables must be wrapped with a suitable piece of
waterproof heat-shrinkable tube!
5. Connect the receiver cable to the CAN2 port of the eBC Controller Pro.
Since the receiver cannot be mounted to the Cargolift before delivery in this case, the receiver must
be secured for transport in a suitable location on the Cargolift!
Receiver
Holder
Strain relief
Cable tie
Mount the Bär Control EVO to the Cargolift with the receiver holder and the
holder for the socket and key switch.