A-GAGE EZ-ARRAY
Instruction Manual
Appendix
A.3.2 ALL Measurements
The ALL Measurements section contains the current values of
all the available measurements. The ALL Measurements data
can be read after every third scan.
Table A–36. ALL Measurements
Input Registers
Member Name
30500
FBB
30501
LBB
30502
TBB
30503
TRN
30504
CBB
30505
FBM
30506
LBM
30507
TBM
30508
CBM
30509
MBB
30510
OD
30511
ID
30512
CFBB
30513
CLBB
30514
O1 FBB
30515
O1 LBB
30516
O2 FBB
30517
O2 LBB
30518
O3 FBB
30519
O3 LBB
30520
CARPET NAP
30521
AO1 PEAK
30522
AO2 PEAK
30523
CARPET EDGE
30524
SPECIAL
Table A–37. Measurements (ALL)
Range
Description
0-1920
Measurements are represented in 4x channel
resolution
Example A–6. Reading ALL Measurements
Request
Response
Field Name
(Hex)
Field Name
(Hex)
Slave Address
41
Slave Address
41
Function
04
Function
04
Starting Address
(HIGH Byte)
77
Byte Count
32
Starting Address
(LOW Byte)
24
Register 30500
(HIGH Byte)
00
Quantity of Registers
(HIGH Byte)
00
Register 30500
(LOW Byte)
00
Quantity of Registers
(LOW Byte)
19
Register 30501
(HIGH Byte)
00
CRC (LOW Byte)
64
Register 30501
(LOW Byte)
00
CRC (HIGH Byte)
BF
…
…
…
…
Register 30524
(HIGH Byte)
00
Register 30524
(LOW Byte)
00
CRC (LOW Byte)
28
CRC (HIGH Byte)
C0
To read ALL Measurements, a read input registers request is
sent starting at address 30500, and requesting 25 registers.
AO1 PEAK and AO2 PEAK Measurements
The AO1 PEAK and AO2 PEAK measurements store the
minimum/maximum values of Analog Output 1 and Analog
Output 2 respectively. When the EZ-ARRAY’s Analog Outputs
are configured to have Peak Detect = Enabled and Peak
Detect Reset = External Communications, then reading these
measurements will reset the Analog Output Peak Detect value.
To enable this mode of operation, the Analog Output’s Config
Flags register (address 40026 – AO1, address 40030 – AO2)
must be configured as shown in Example A–7.