18
P/N 130426 Rev.
D
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
A-GAGE EZ-ARRAY
Instruction Manual
Installation
wh
wh
ye
ye
gn
gn
rd
rd
gy
0-2V dc
gy
bare
bare
pk
bu
bn
pk
bu
bn
Sync
Power Supply V+
10-30V dc
Power
Power Supply V-
Sync
Power Supply V+
Power Supply V-
V Out 1
V Out 2
Out 1
Out 2
Teach
Shield
Shield
Receiver
Emitter
Load
Load
+
–
+
–
+
–
Figure 3-5. NPN hookup
Receiver
Emitter
wh
wh
ye
ye
gn
gn
rd
rd
gy
0-2V dc
gy
bare
bare
pk
bu
bn
pk
bu
bn
Sync
Power Supply V+
Power Supply V-
Sync
Power Supply V+
Power Supply V-
V Out 1
V Out 2
Out 1
Out 2
Teach
Shield
Shield
Load
Load
+
–
+
–
10-30V dc
Power
+
–
Figure 3-6. PNP hookup
Figure 3-4. Serial communication hookup
3.3 Hookups
Refer to Figures 3-4, 3-5, and 3-6 for the appropriate hookup
information.
Serial Connection
This connection is used only when the PC interface is also used.
The receiver has a Modbus RTU-485 serial interface. A separate
5-pin Euro-style connection is provided at the end opposite from
the power cable connection to electrically connect the serial
communication cable to an external PC or PLC. Refer to Figure
3-4; the white wire is connected to the Modbus D1/B/ + terminal
and the black wire is connected to the D0/A/ − terminal.
Inputs
Refer to Figures 3-5 and 3-6 for standard hookup information.
Receiver gray wire:
The receiver has an input that can be used
as a gate input or for remote teach. To initiate remote teach,
alignment, and gating functions, tie the wire through a switch to
sensor common. See Sections 1.7 and 5.7 for more information.
Outputs
Refer to Figures 3-5 and 3-6 for standard hookup information
and Section 2.6 Sensor Specifications for further electrical
requirements.
Analog white and yellow wires:
The receiver has two analog
outputs. Depending on receiver model, both outputs are either
voltage or current. The white wire is referenced as analog output
1; the yellow wire is referenced as analog output 2. Both analog
current and voltage will source current through an external load
to sensor common.
Discrete Outputs:
The receiver has two discrete outputs;
the green wire is referenced as discrete #1, and the red wire,
discrete #2. Depending on model, both outputs are either NPN
or PNP, unless the polarity is altered via the PC interface. Refer
to Section 2.6 Specifications for further electrical requirements.
Sync (Pink) Wire
The emitter and receiver are electrically synchronized via the
pink wire. The emitter and receiver pink wires must only be
electrically connected together.
Modbus
white
black
blue
D1/B/+
D0/A/–
common
brown
gray
White
Brown
Blue
Gray
Black
Male Connector Pinout
White: D1 / B / +
Black: D0 / A / –
Blue: Common