Technical data
4.1.5.1.5 USB In interface
The USB In interface is a USB 2.0 type B interface that is used to transfer USB data. It must be connected to a USB
interface on the output device (e.g. B&R industrial PC) if DVI operation or SDL operation with a USB type A/B cable
was chosen as the transfer method. For possible transfer methods, see section
"Connection options" on page 17
.
If the interface is connected to an output device (e.g. B&R industrial PC), then USB 2.0 transfer rates are possible
on the USB1 and USB2 interfaces.
Description
Figure
Standard
USB 2.0
Variant
Type B, female
Transfer rate
Low speed (1.5 Mbit/s)
Full speed (12 Mbit/s)
High speed (480 Mbit/s)
Current-carrying capacity
1)
Max. 500 mA
Cable length
Max. 5 m (without hub)
-
1)
The USB interface is protected by a maintenance-free "USB current-limiting switch" (max. 500 mA).
4.1.5.1.6 Serial interface
The serial interface is only available for use with a single-touch display in DVI operation. It is used to transfer data
from the resistive touch screen and must be connected to a serial interface on the output device.
COM interface
RS232
Type
Modem supported, not galvanical-
ly isolated, DSUB, 9-pin, female
UART
16550-compatible, 16-byte FIFO buffer
Transfer rate
Max. 115 kbit/s
Bus length
Max. 15 m
Pin
Pinout
1
NC
2
RXD
3
TXD
4
NC
5
GND
6
NC
7
RTS
8
CTS
9
NC
1
5
6
9
4.1.5.1.7 Brightness controls
The brightness controls can be used to set the brightness of the backlight
on the Automation Panel in DVI operation. Buttons have no function during
SDL operation; the brightness can be set via the B&R Control Center, for
example.
Automation Panel 9x3 User's manual 2.01
39