www.balluff.com
7
english
3.1
Construction
Electrical connection:
The electrical connection is made
via a connector (see Type code on page 20).
Housing:
Aluminum housing containing the waveguide
and processing electronics.
Magnet:
Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see Accessories on
Nominal length:
To optimally adapt the BTL to the
application, the following nominal lengths are available:
Nominal length
Grading
50…4572 mm
5 mm
3.2
Function
The BTL contains the waveguide which is protected by an
aluminum housing. A magnet is moved along the
waveguide. This magnet is connected to the system part
whose position is to be determined.
The magnet defines the position to be measured on the
waveguide.
An internally generated INIT pulse interacts with the
magnetic field of the magnet to generate a torsional wave
in the waveguide which propagates at ultrasonic velocity.
The component of the torsional wave which arrives at the
end of the waveguide is absorbed in the damping zone to
prevent reflection. The component of the torsional wave
which arrives at the beginning of the waveguide is
converted by a coil into an electrical signal. The travel time
of the wave is used to calculate the position. The
measuring value is output as a 32-bit value with a sign
relative to the null point.
3.3
LED display
In normal operation the LED indicates the
operating states of the BTL.
LED
Operating state
Green
Normal function without IO-Link
communication
Magnet is within the limits.
Green
flashing
inversely
Normal function with IO-Link communication
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
Tab. 3-1: LED display
Fig. 3-1: BTL6…, construction
3
Construction and function
2)
13
73
73
~80
~80
~250
~250
15
50
34.8
68
24.8
20.8
M12
1) Unusable area
2) Not included in scope
of delivery
1)
Nominal length =
Measuring range
Null point
End point
Output signal rising:
Error signal
100 %
0 %
BTL5-P-3800-2 magnet
1)
Mounting clamps with insulating bushes
and ISO 4762 M5x25 cylinder-head screws,
max. tightening torque 2 Nm
2)
LED
BTL6-U110-M _ _ _ _ -PF-S4
Magnetostrictive Linear Position Sensor – Profile Style
Summary of Contents for BTL6-U110-M****-PF-S4 series
Page 2: ...www balluff com...
Page 3: ...BTL6 U110 M_ _ _ _ PF S4 Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 24: ......
Page 25: ...BTL6 U110 M_ _ _ _ PF S4 User s Guide english...
Page 26: ...www balluff com...
Page 46: ......
Page 47: ...BTL6 U110 M_ _ _ _ PF S4 Notice d utilisation fran ais...
Page 48: ...www balluff com...
Page 68: ......
Page 69: ...BTL6 U110 M_ _ _ _ PF S4 Manuale d uso italiano...
Page 70: ...www balluff com...
Page 90: ......
Page 91: ...BTL6 U110 M_ _ _ _ PF S4 Manual de instrucciones espa ol...
Page 92: ...www balluff com...