16
english
7.1
Accuracy
The specifications are typical values for BTL6-U… at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2, BTL6-A-3800-2,
BTL6-A-3801-2, BTL5-F-2814-1S or BTL5-T-2814-1S
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
5 µm
Repeat accuracy
≤
30 µm
Sampling rate
(dependent on the nominal length)
Max. 1 kHz
Non-linearity with a constant distance
between the magnet and profile
Nominal length
≤
500 mm
Nominal length > 500 mm
±200 µm
±0.04 % FS
Temperature coefficient
1)
≤
30 ppm/K
Velocity detectable max.
10 m/s
7.2
Ambient conditions
Ambient temperature
-
25°C…+70°C
Storage temperature
-
40°C…+100°C
Humidity
< 90 %,
non-condensing
Shock rating
Continuous shock
per EN 60068-2-27
3)
50 g/6 ms
50 g/2 ms
Vibration
per EN 60068-2-6
3)
12 g,
10…2000 Hz
Degree of protection
per IEC 60529
IP67
(when attached)
2)
7.3
Supply voltage (external)
Voltage, stabilized
4)
18…30 V DC
Ripple
≤
0.5 V
PP
Current draw
(at 24 V DC)
≤
150 mA
Inrush current
≤
3 A
Reverse polarity protection
Up to 36 V
Overvoltage protection
Up to 36 V
Dielectric strength
(GND to housing)
500 V DC
7.4
IO-Link interface
Transfer protocol
IO-Link 1.1
Transfer rate
COM3 (230.4 kBaud)
Cycle time min.
1 ms
Master-device process data
0 bytes
Device-master process data
4 bytes
PD cycle on 1.0 master min.
4 ms
PD cycle on 1.1 master min.
1 ms
Output value
Position in µm
Data format
32-bit signed
Error value
0x7FFFFFF
7.5
Dimensions, weights
Housing height
20.8 mm
Nominal length
50…4572 mm
Weight (depends on length)
Approx. 1 kg/m
Housing material
Aluminum
1)
Nominal length 500 mm, magnet in the middle of the measuring range
2)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
level.
3)
Individual specifications as per Balluff factory standard, resonant
frequencies excluded
4)
For
: The BTL must be externally connected via a limited-energy
circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
7
Technical data
BTL6-U110-M _ _ _ _ -PF-S4
Magnetostrictive Linear Position Sensor – Profile Style
Summary of Contents for BTL6-U110-M****-PF-S4 series
Page 2: ...www balluff com...
Page 3: ...BTL6 U110 M_ _ _ _ PF S4 Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 24: ......
Page 25: ...BTL6 U110 M_ _ _ _ PF S4 User s Guide english...
Page 26: ...www balluff com...
Page 46: ......
Page 47: ...BTL6 U110 M_ _ _ _ PF S4 Notice d utilisation fran ais...
Page 48: ...www balluff com...
Page 68: ......
Page 69: ...BTL6 U110 M_ _ _ _ PF S4 Manuale d uso italiano...
Page 70: ...www balluff com...
Page 90: ......
Page 91: ...BTL6 U110 M_ _ _ _ PF S4 Manual de instrucciones espa ol...
Page 92: ...www balluff com...