Parameter Data
Index
Sub-
index
Parameter
Size
Access
Parameter-
management
Default value
Identification data
0x0010
0
Vendor Name
7 bytes
Read Only
—
"BALLUFF"
0x0011
0
Vendor Text
15 bytes
Read Only
—
"www.balluff.com"
0x0012
0
Product Name
Max. 40 bytes
Read Only
—
"BTL6-U110-Mxxxx-PF-
S4"
0x0013
0
Product ID
12 bytes
Read Only
—
"BTL6PFIOLxxx"
0x0014
0
Product Text
27 bytes
Read Only
—
"Balluff Position
Transducer"
0x0015
0
Serial Number
Max. 18 bytes
Read Only
—
"YYMMDDXXXXXXXX"
0x0016
0
Hardware Revision
2 bytes
Read Only
—
"XX"
0x0017
0
Firmware Revision
9 bytes
Read Only
—
"vX.XX.XXX"
Parameters
0x000C
0
Device Access Locks
2 bytes
Read/Write
Yes
0x000D
3
Profile Characteristic
6 bytes
Read Only
No
0x00 0x01 0x80 0x00
0x80 0x02
0x000E
0
PD Input Descriptor
3 bytes
Read Only
No
0x03 0x20 0x00
0x0018
0
Application Specific Tag
32 bytes
Read/Write
Yes
0x0040
0
Null point offset
4 bytes
Read/Write
No
0
0x0041
0
Takeover of null point
offset
Boolean
(1 byte)
Write Only
No
Tab. 6-3: Parameter data of IO-Link interface
6
IO-Link interface (continued)
Access to subindex 0 address the entire object
of an index. Access of subindices > 0 addres-
ses the individual elements of an index.
Device Access Locks
With this standard parameter, it is possible to activate or
deactivate certain functions of the IO-Link device. With
BTL, there is the option to lock the function of the parame-
ter manager. To do so, bit 1 of the 2-byte value must be
set to 1 (locked). In order to unlock the parameter mana-
ger, bit 1 is set to 0.
Bit
Function
0
Lock parameter access (not supported)
1
Lock parameter management (supported)
2
Lock local parameterization (not supported)
3
Lock local user interface (not supported)
4…15 Reserved
Tab. 6-4: Lock parameter data
Profile Characteristic
This parameter indicates which profile is supported by
the IO-Link device.
BTL supports the smart sensor profile with the following
function classes:
– Subindex 1 (Profile Identifier -> DeviceProfileID):
0×0001 (Smart Sensor Profile)
– Subindex 2 (Profile Identifier -> FunctionClassID):
0×8000 (Device Identification Objects)
– Subindex 3 (Profile Identifier -> FunctionClassID):
0×8002 (ProcessDataVariable)
PD Input Descriptor
This parameter describes the composition of the process
data variables used.
The BTL processes the process data variable as follows:
Subindex 1: 0x032000
– 0x03 -> Data type = IntegerT
– 0x20 -> Data size = 32 bits
– 0x00 -> Offset = 0 bits
Application Specific Tag
The
Application Specific Tag
makes it possible to assign
the IO-Link device an arbitrary, max. 32-byte string. This
can only be used for application-specific identification and
applied in the parameter manager. The entire object is
accessed via subindex 0.
BTL6-U110-M _ _ _ _ -PF-S4
Magnetostrictive Linear Position Sensor – Profile Style
Summary of Contents for BTL6-U110-M****-PF-S4 series
Page 2: ...www balluff com...
Page 3: ...BTL6 U110 M_ _ _ _ PF S4 Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 24: ......
Page 25: ...BTL6 U110 M_ _ _ _ PF S4 User s Guide english...
Page 26: ...www balluff com...
Page 46: ......
Page 47: ...BTL6 U110 M_ _ _ _ PF S4 Notice d utilisation fran ais...
Page 48: ...www balluff com...
Page 68: ......
Page 69: ...BTL6 U110 M_ _ _ _ PF S4 Manuale d uso italiano...
Page 70: ...www balluff com...
Page 90: ......
Page 91: ...BTL6 U110 M_ _ _ _ PF S4 Manual de instrucciones espa ol...
Page 92: ...www balluff com...