www.balluff.com
43
english
Ø window 1 = 4.6
2
5
9
6
1
3
5
8
9
4
6
5
8
7
4
9
6
1
3
5
Ø window 2 = 5.8
2
5
9
6
1
3
5
8
9
4
6
5
8
7
4
9
6
1
3
5
Ø window 3 = 6
2
5
9
6
1
3
5
8
9
4
6
5
8
7
4
9
6
1
3
5
Ø window 4 = 4.8
2
5
9
6
1
3
5
8
9
4
6
5
8
7
4
9
6
1
3
5
Fig. 6-6: Periodic window approach
Fig. 6-7 shows the moving average using the method of
the periodic window.
Fig. 6-7:
Moving average (window width 9)
Value
Periodic window
Periodic window approach (example)
6.4.3 Process Data
Object ID
Name
Description
Direction
0x0053 (83) Minimum
Minimum value
Input
0x0054 (84) Maximum
Maximum value
Input
0x0055 (85) Average
Average
Input
0x0056 (86) Moving Average
Repeatedly calculated average value
Input
0x0057 (87) Status
Status value
Input
0x0058 (88) Number Of Samples
Number of measurement values for the calculation of minimum,
maximum and average
Input
Tab. 6-20: Basic statistics – process data
6
Secondary Device Functions (continued)
BOS R254K-UUI-LS10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LS10-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LS10 S4 ...
Page 2: ...www balluff com ...
Page 3: ...BOS R254K UUI LS10 S4 Konfigurationsanleitung deutsch ...
Page 4: ...www balluff com ...
Page 88: ......
Page 89: ...BOS R254K UUI LS10 S4 Configuration Guide english ...
Page 90: ...www balluff com ...