52
english
Current Operating Hours
This parameter saves the value of the operating hours
since the last commissioning in seconds.
Total Operating Hours
This parameter saves the value of the operating hours
since the first commissioning in seconds.
Custom Operating Hours
This parameter saves the value of the operating hours
since the last reset in seconds.
Operating Hours Saving Mode
The current storage behavior can be set.
Value
Meaning
Description
0x00 (0)
Dynamic
The first save operation is
performed 1 minute after
switching on; the storage
interval than doubles after
every save operation. This is
limited to a storage interval
of 12 minutes. The intervals
are 1, 2, 4, 8, 12 minutes.
0x01 (1)
Static
Operating hours counters
are stored every 12 minutes.
Tab. 6-35: Operating hours counter – Operating hours saving mode
6
Secondary Device Functions (continued)
6.6.5 System Commands
Command Value
Device Action
0x81 (129)
Application Reset
– Resets
Custom Operating Hours
to the
default value.
0x82 (130)
Restore Factory Settings
– Resets
Custom Operating Hours
and
Operating Hours Saving Mode
to
the default value.
0xA5 (165)
Maintenance Reset
– Resets
Custom Operating Hours
to the
default value.
Tab. 6-36: Operating hours counter – System Commands
For an overview of all System Commands, see section 3.5
BOS R254K-UUI-LS10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LS10-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LS10 S4 ...
Page 2: ...www balluff com ...
Page 3: ...BOS R254K UUI LS10 S4 Konfigurationsanleitung deutsch ...
Page 4: ...www balluff com ...
Page 88: ......
Page 89: ...BOS R254K UUI LS10 S4 Configuration Guide english ...
Page 90: ...www balluff com ...