78
english
7.6
LED Meaning and Configuration
7.6.1 Description
Only the signal with the highest priority is displayed. The
signals are listed in descending priority.
Balluff Standard
LED 1 (operating status and communication)
Name
Signal
Meaning
Failure
Static red
General error
Communication
Green alternating with LED
off at ratio of 10:1, 1 s
period
IO-Link communication is active. The device is ready.
Ready
Static green
The device is ready.
Tab. 7-18: LED meaning and configuration – Balluff Standard, LED1
LED 2 (Indication/Warning/Teach/Device Discovery)
Name
Signal
Meaning
Device Discovery
Blue, flashing, 3 Hz
The Device Discovery can be activated via a system
command to find the device again.
Short Circuit Pin 2 / Pin 4
Red, flashing, 3 Hz
Short circuit at pin 2 or pin 4
Maintenance Required
Blue, static
Maintenance must be performed.
Out of Specification
Yellow, flashing, 3 Hz
The device is operated outside of specifications. A
reliable measurement signal can no longer be ensured.
Tab. 7-19: LED meaning and configuration – Balluff Standard, LED2
7
System Functions (continued)
BOS R254K-UUI-LS10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LS10-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LS10 S4 ...
Page 2: ...www balluff com ...
Page 3: ...BOS R254K UUI LS10 S4 Konfigurationsanleitung deutsch ...
Page 4: ...www balluff com ...
Page 88: ......
Page 89: ...BOS R254K UUI LS10 S4 Configuration Guide english ...
Page 90: ...www balluff com ...