Secondary Device Functions (continued)
6.13.4 System Commands
For an overview of all System Commands, see section 3.5
6.13.5 Events
Event Code
Event Type
Description
Device Status
0x8D12 (36114)
Warning
The defined threshold of the device-internal
humidity was exceeded.
►
Check installation and ambient conditions.
1 – Maintenance-Required
Tab. 6-65: Humidity detection – Events
6.14 Storage Usage Monitoring
6.14.1 Description
All variable data is stored in a permanent memory on the
device. The data is stored in various segments for different
access and usage purposes.
Because the number of write cycles in the permanent
memory is limited, the number in each segment is
monitored by a counter.
All data segments are protected with a CRC32 checksum.
6.14.2 Events
Event Code
Event Type
Description
Device Status
0x8D22 (36130)
Warning
Warning limit for write cycles reached –
maintenance monitoring no longer guaranteed – for
information purposes only.
0 – Device is operating
properly.
0x8D23 (36131)
Error
Write cycle limit reached – saving no longer ensured
– replacement recommended.
1 – Maintenance-Required
0x8D24 (36132)
Warning
Parameter write error – An error occurred while
writing the data – for information purposes only.
0 – Device is operating
properly.
Tab. 6-66: Storage usage monitoring – Events
BOS R254K-UUI-LS10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LS10-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LS10 S4 ...
Page 2: ...www balluff com ...
Page 3: ...BOS R254K UUI LS10 S4 Konfigurationsanleitung deutsch ...
Page 4: ...www balluff com ...
Page 88: ......
Page 89: ...BOS R254K UUI LS10 S4 Configuration Guide english ...
Page 90: ...www balluff com ...