www.balluff.com
79
english
6.2
Diagnosis Suppression
6.2.1 Description
Diagnosis suppression is used to suppress diagnosis
messages from the device. There are two possibilities here:
– Diagnosis suppression level that permits a general
suppression of messages of a certain level (message,
warning, error).
– Event-code suppression of up to 5 events as a list or
via a teach-in.
6.2.2 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Diagnosis
Level
Configuration
0x0070 (112)
0
R/W
1 byte
ENUM
Yes
0
Event Code
Suppression
0x0071 (113)
0
R/W
10 bytes
UINT16
Yes
0
1-5
R/W
2 bytes
Event Code
Suppression
Teach-in
0x0072 (114)
0
W
2 bytes
UINT16
n/a
n/a
Event Code
Suppression
Delete
0x0073 (115)
0
W
2 bytes
UINT16
n/a
n/a
Tab. 6-4: Diagnosis suppression – ISDU
6.2.3 Diagnosis Level Configuration
This parameter offers the possibility to select an output
level for events.
This index is part of the data management and is stored in
non-volatile memory.
Value
Diagnosis Level
Descriptions
0
All events
All diagnosis messages are reported (default setting).
1
Warnings and errors
All warnings and errors are reported – messages are
suppressed.
2
Error
Only events of type error are reported.
3
No events
All diagnosis messages from the device are suppressed.
Tab. 6-5: Diagnosis suppression – Diagnosis level configuration
6
System Functions (continued)
BOS R254K-UUI-LH10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LH10-S4
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R254K UUI LH10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI LH10 S4 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 99: ...BOS R254K UUI LH10 S4 IO Link Configuration english...
Page 100: ...www balluff com...
Page 195: ......