60
english
5.7
Operating Hours Counter
5.7.1 Description
The operating hours counter can record the operating
hours of a device accurately to the second. There are a
total of three operating hours counters. In addition to an
operating hours counter for the operating hours since the
start of the device, there is a total operating hours counter
and a customer-specific operating hours counter that can
be reset. The storage rate can be set and no operating
hours are stored upon reaching 500000 storage cycles.
The output of the operating hours can serve as a time
control for the service interval as well as for preventative
maintenance. Schedules for regular service can be tied to
the operating hour values. Moreover, a high value of the
total operating hours is indicative of intensive use of a
sensor and possible deterioration of the performance. The
risk of failure can be countered preventatively through
replacement.
5.7.2 Algorithm
While the counter is incremented every second, the
storage rate doubles after each save operation. Starting
with a save operation after 1 minute, then after 2 minutes,
then after 4 minutes, then after 8 minutes, until a maximum
storage rate of every 12 minutes.
5.7.3 Process Data
Object ID
Name
Description
Direction
0x001B (27)
Current Operating Hours
Output of the current operating hours counter
Input
0x001C (28)
Total Operating Hours
Output of the total operating hours counter
Input
0x001D (29)
Custom Operating Hours
Output of a user-defined operating hours counter
Input
Tab. 5-36: Operating hours counter – Process data
on page 9.
5.7.4 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Current
Operating
Hours
0x0057 (87)
1
R
4 bytes
UINT32
No
0
Total
Operating
Hours
0x0057 (87)
2
R
4 bytes
UINT32
No
0
Custom
Operating
Hours
0x0057 (87)
3
R
4 bytes
UINT32
No
0
Operating
Hours Saving
Mode
0x0074 (116)
0
R/W
1 byte
ENUM
Yes
0
Tab. 5-37: Operating hours counter – ISDU
5
Secondary Device Functions (continued)
BOS R254K-UUI-LH10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LH10-S4
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R254K UUI LH10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI LH10 S4 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 99: ...BOS R254K UUI LH10 S4 IO Link Configuration english...
Page 100: ...www balluff com...
Page 195: ......