Primary Device Functions (continued)
4.2
Device Discovery
4.2.1 Description
With the Ping function, an IO-Link device can be found
again by starting signaling on the LED of the device by
means of a system command.
4.2.2 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Ping Timeout 0x00FE (254)
0
R/W
2 bytes
INT
Yes
1
Tab. 4-2: Device detection – ISDU
Ping Timeout
The
Ping Timeout
parameter sets the duration of the ping
signal that is displayed via LEDs.
The value is specified minutes. The value range from 0 to
30 minutes is allowed. If the parameter is set to 0, the ping
signal is deactivated. The parameter is reset by
Application
Reset
and
Factory Reset
(also see section
on page 81).
4.2.3 System Commands
Command Value Device Action
0xAF (175)
Start Ping
Tab. 4-3: Device detection – System Commands
BOS R254K-UUI-LH10-S4
Photoelectric Sensors