![Balluff BOS R254K-UUI-LH10-S4 Manual Download Page 127](http://html1.mh-extra.com/html/balluff/bos-r254k-uui-lh10-s4/bos-r254k-uui-lh10-s4_manual_3698811127.webp)
www.balluff.com
29
english
Teach-In Result
Outputs the current status of the currently active or of the
last teach-in process:
Teach-In
Flags SP
Teach-In State
0
0
TP2
TP1
Bit 7
Bit 0
Tab. 4-9: Switching profiles – Teach-In Result
Bit
position
Meaning
Description
7
–
Reserved
6
–
5
Flag SP TP2 0 = Teach point not detected
or not successfully
detected.
1 = Teach point successfully
detected.
4
Flag SP TP1
3…0
State
0 = IDLE – No currently active
teach process
1 = SUCCESS – Last process
was successful.
2 = Reserved
3 = Reserved
4 = WAIT FOR COMMAND
– Wait for next command.
5 = BUSY – Process active
6 = Reserved
7 = ERROR – Last process
was not successful.
Tab. 4-10: Switching profiles – Teach-In Result