20
english
3.6
Events
Event Code Event Type
Description
Device Status
0x1850
(6224)
Notification
Process data profile selection cannot be used –
default value is used.
0 – Device is operating properly.
0x1851
(6225)
Notification
Process Data Update Timeout – for information
purposes only
0 – Device is operating properly.
0x1852
(6226)
Warning
Multiple Process Data Update Timeout – for
information purposes only
0 – Device is operating properly.
0x1860
(6240)
Warning
Warning about service life of transmitter.
►
Replace sensor during next maintenance cycle.
1 – Maintenance-Required
0x4000
(16384)
Error
Temperature fault – overload
– The device is
operated outside of the device-specific temperature
limits. Risk of device damage.
4 – Failure
0x4210
(16912)
Warning
Device temperature overrun – clear heat of source
– risk of device damage. The device is too hot.
►
Remove heat source, provide the device with
heat insulation if necessary.
2 – Out-of-Specification
0x4220
(16928)
Warning
Device temperature underrun – insulate device
– risk
of device damage. The device is too cold.
►
Insulate the device.
2 – Out-of-Specification
0x5110
(20752)
Warning
Primary supply voltage exceeded
►
Check for deviations in the supply.
2 – Out-of-Specification
0x5111
(20753)
Warning
Primary supply voltage below minimum value
►
Check for deviations in the supply.
2 – Out-of-Specification
0x8CD0
(36048)
Warning
Inclination alarm
►
Check installation.
1 – Maintenance-Required
0x8CD1
(36049)
Warning
Vibration alarm
►
Check machine.
0 – Device is operating properly
0x8CFF
(36095)
Warning
Low signal quality level
►
Check alignment of sensor
►
Clean sensor
0 – Device is operating properly.
0x8D07
(36103)
Warning
The calculation of the basic statistics was stopped
automatically to avoid a buffer overflow.
0 – Device is operating properly.
0x8D08
(36104)
Warning
Speed value is below the limit.
0 – Device is operating properly.
0x8D09
(36105)
Warning
Speed value is above the limit.
0 – Device is operating properly.
0x8D0B
(36107)
Warning
Overload or short circuit at pin 2
►
Check wiring.
2 – Out-of-Specification
0x8D0D
(36109)
Warning
Incorrect load/cable breakage, analog current output
pin 2
►
Check wiring or connected devices.
2 – Out-of-Specification
0x8D0E
(36110)
Notification
The time has elapsed. This event reports the timeout
of the minimum value/maximum value/average
calculation.
It does not report a timeout for the calculation of the
moving average because the timer repeats and it
does not indicate the end of the calculation.
0 – Device is operating properly.
0x8D10
(36112)
Warning
Device temperature upper warning
– The set upper
temperature warning threshold has been exceeded.
0 – Device is operating properly
3
Overview of IO-Link Data and Functions (continued)
BOS R254K-UUI-LH10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LH10-S4
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R254K UUI LH10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI LH10 S4 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 99: ...BOS R254K UUI LH10 S4 IO Link Configuration english...
Page 100: ...www balluff com...
Page 195: ......