Operator’s Manual 69
Note: After the machine has retracted the Right/Left Fetcher Swing cylinders, the Left
Fetcher Out reed switch should be lined up with the Left Fetcher magnet, which turns
the switch on. This is what the machine is waiting for.
- If the Left Fetcher Swing cylinder is fully retracted,
- Check the air gap distance between the Left Fetcher Out reed switch and the
magnet. The distance should be a maximum of 1/8 inch (3 mm). If it is within the
suggested range then the reed switch needs to be replaced.
- If the Left Fetcher Swing cylinder is partially retracted,
- Check that a foreign object is not preventing the Left Fetcher Swing cylinder
from retracting.
- Check to see if the Left Fetcher is hitting the Strap Guide Arms. If it is, check
that the Strap Guide Arms are in time with each other. They should be the same
height. If their heights vary ½ inch (12.5 mm) or greater then they are at least one
gear tooth out of time. A quick way to check their heights is to compare the
distance between the Vertical Plunger plates to the Strap Guide plates. In order to
prevent the Strap Guide arms from getting out of time, keep their chains tight.
- Electric power or hydraulic power or hydraulic return has been disconnected or
shut off from machine.
- If the Left Fetcher Swing cylinder is still extended,
- Check that hydraulic power is still on to the machine and that return line is still
connected.
- Check that a foreign object is not preventing the Left Fetcher Swing cylinder from
retracting.
- Check that the directional valve is not stuck.
053 Waiting for Right Fetcher Out reed switch to be on.
Note: After the machine has retracted the Right/Left Fetcher Swing cylinders, the Right
Fetcher Out reed switch should be lined up with the Left Fetcher magnet, which turns
the switch on. This is what the machine is waiting for.
- If the Right Fetcher Swing cylinder is fully retracted,
Summary of Contents for GFC 100
Page 2: ......
Page 4: ......
Page 8: ...Operator s Manual 3 Serial Number Location...
Page 10: ...Operator s Manual 5 Safety Decals...
Page 11: ...Operator s Manual 6 Safety Decals...
Page 12: ...Operator s Manual 7 Safety Decals...
Page 13: ...Operator s Manual 8...
Page 31: ...Operator s Manual 26 Hydraulic Manifold Layout Front Manifold...
Page 32: ...Operator s Manual 27 Inside Banding Box Manifold...
Page 33: ...Operator s Manual 28 Outside Banding Box Manifold...
Page 34: ...Operator s Manual 29 Electrical Layout Front Relay Box located behind banding drums...
Page 35: ...Operator s Manual 30 Band Relay Box located in Banding Box...
Page 52: ...Operator s Manual 47 If the Vertical Plunger cylinder is fully retracted...