4.9 Connection summary - minimum wiring (remote axis)
As a guide, Figure 32 shows an example of the typical minimum wiring required to allow the
NextMove
e
100 and a single axis EPL servo amplifier (e.g. MicroFlex
e
100) to work together.
Details of the connector pins are shown in Table 3.
Remote (EPL)
servo amplifier
(MicroFlex
e
100)
Drive
Enable
Host PC
+24 V
control
supply
+24V
0V
E1 / E2
Ethernet
X1
NextMove
e
100
9
10
X12
Common
earth/ground
USB connection
US
B
Ethernet
Figure 32 - Example minimum system wiring