www.baldormotion.com
3-2 Basic Installation
MN1941
3.1.2 Mounting the NextMove
e
100
Before touching the unit be sure to discharge static electricity from your body and
clothing by touching a grounded metal surface. Alternatively, wear an earth strap
while handling the unit.
Ensure you have read and understood the location requirements in section 3.1.1. Mount the
NextMove
e
100 using the supplied M4 screws. For effective cooling, the NextMove
e
100 must
be mounted on a smooth non-flammable vertical surface. Orientation must be as shown in
Figure 1, with the two slots in the metal carrier / heat sink assembly at the bottom.
140
(5
.51)
129
(5
.08)
170
(6.69)
250
(9.84)
All dimensions shown as
mm
(inches)
40.3
(1
.59)
Mounting keyhole and slot detail
A
B
C
A
4.5 mm
B
10 mm
C
11 mm
A
Drawings not to scale
Figure 1 - Package dimensions
There must be at least 20 mm (0.8 in) clearance between the NextMove
e
100 and neighboring
equipment to allow sufficient cooling by natural convection. Remember to allow additional space
around the edges to accommodate the mating connectors and associated wiring. For example,
70 mm (2.8 in) clearance will be required for connection of the serial port cable.
NOTICE
Summary of Contents for NXE100-1608Dx
Page 1: ......
Page 2: ......
Page 16: ...www baldormotion com 3 4 Basic Installation MN1941 ...
Page 50: ...www baldormotion com 4 34 Input Output MN1941 ...
Page 77: ...www baldormotion com Operation 5 27 MN1941 Figure 37 The NextMove e100 servo loop ...
Page 98: ...www baldormotion com 6 8 Troubleshooting MN1941 ...
Page 110: ...Index MN1941 ...
Page 112: ...Comments MN1941 Thank you for taking the time to help us ...
Page 113: ......
Page 114: ......