66
66
Installation:
Must be away from inductive and capacitive interference source as conductor, relays,
1.
engines, switch power pack clocked controllers, etc..
Must be wired separately from heavy-duty current wires.
2.
Must be kept a distance to interference sources.
3.
Ensure to apply tape on clean, dry and plain surface.
4.
For the best adhesion, please apply the tape with ambient temperature: 70-100°F.
5.
We recommend to make a chamfer on the machine to install the tape.
6.
Recommend Gap between tape and sensor: 1mm.
< +/- 5
< +/- 5
Magnetic tape
< +/- 1,5
Gap
2,5 mm max.
+/- 3
mm
4
17
4
3.5
25
10
11.2
6
15
Gap (sensor
– tape)
Summary of Contents for STS-14120DRO
Page 55: ...51 51...
Page 56: ...52 52 Load Datum Values Only In ABS Mode A Description...
Page 57: ...53 53...
Page 58: ...54 54 B Load Datum...
Page 59: ...55 55 C Troubleshooting...
Page 60: ...56 56 Select Counting Direction...
Page 61: ...57 57...
Page 62: ...58 58 Set Device Resolution...
Page 63: ...59 59...
Page 64: ...60 60 Enable and Disable Specified Parameter...
Page 65: ...61 61...
Page 66: ...62 62...
Page 68: ...64 64 Parameter Setting...
Page 71: ...67 67 External Dimension Mounting Installation 10...
Page 73: ...69 69...
Page 74: ...70 70 B Troubleshooting...
Page 75: ...71 71...
Page 115: ...111 111 NOTES...