22
22
SLIDING TABLE INSTALLATION
The sliding table was installed and adjusted for parallelism at the factory. DO NOT change or
1.
damage the the adjusting bolts (A) during installation of the sliding table.
Clean the rust preventative off of the contact surfaces (B) for the main cabinet and the sliding
2.
table (Total 3 contact surfaces).
Remove the access covers (C) from behind the 2 outer mouning points. The center mount is
3.
accessed through the clearance slot (D) for tilting the blade.
Note
Use care when placing the sliding table on the contact surfaces so as not to
damage the surfaces. The sliding table may require from 4~ 6 workers to lift safely.
Using the assistants, lift the sliding table onto the machine taking care not to damage the
4.
contact spots. Looking closely at the edge of the sliding table base, you should be able to
see the spots where the adjusting bolts have contacted the sliding table. Use these marks to
help align the bolt holes.
Install the 3 mounting bolts hand tight.
5.
Verify that the sliding table base is tight against the adjusting bolts and slightly tighten the 3
6.
mounting bolts.
A
A
B
C
D
Summary of Contents for STS-14120DRO
Page 55: ...51 51...
Page 56: ...52 52 Load Datum Values Only In ABS Mode A Description...
Page 57: ...53 53...
Page 58: ...54 54 B Load Datum...
Page 59: ...55 55 C Troubleshooting...
Page 60: ...56 56 Select Counting Direction...
Page 61: ...57 57...
Page 62: ...58 58 Set Device Resolution...
Page 63: ...59 59...
Page 64: ...60 60 Enable and Disable Specified Parameter...
Page 65: ...61 61...
Page 66: ...62 62...
Page 68: ...64 64 Parameter Setting...
Page 71: ...67 67 External Dimension Mounting Installation 10...
Page 73: ...69 69...
Page 74: ...70 70 B Troubleshooting...
Page 75: ...71 71...
Page 115: ...111 111 NOTES...