Test Procedure
© b2 electronic GmbH
DHV0086 Rev06
58
Step
Procedure
(Configure auto test sequence)
NS08: Voltage Rating
Set voltage rating:
• 0-50 kV
This is a characteristic of the DUT and
does NOT refer to the test voltage!
NS09: Next Step
Press “Next” to continue.
NS10: Test Type
Select one of the following test types:
• VLF withstand test
• VLF Tan Delta test
• DC test
• sheath test
The test type depends on the DUT type or
guide.
NS11: Test Standard
Set the test standard:
• IEEE400.2-2013
• HD620
• No guide
Guide:
If you select a test standard (guide), some
of the parameters are locked.
e.g. IEEE 400.2 -> no DC Test possible