Test Procedure
© b2 electronic GmbH
DHV0086 Rev06
73
5�4 Interrupting a Test
Once a test has started, it can be interrupted at any time. It is recommended
to select the appropriate interruption method to each situation
Step
Procedure
(Interrupting a test)
Routine STOP
(Non-emergency)
When a test is in progress, “Stop” is
highlighted on the display screen.
To interrupt the test, push in/click the
navigation knob
41
• HVA software deactivates HV.
• Test stops.
Alternative
When a test is in progress, press the HV
switch
40
to deactivate high voltage.
• HVA hardware deactivates HV.
• Test stops.
Emergency Stop
In an emergency situation, press the
emergency off button
42
to shutdown the
system.
• HVA hardware deactivates HV.
• Test stops.