UMAX140610. LIN
– J1939 CAN Protocol Converter with PWM Output. Version 1
Page: 26-81
Configuration parameters of the
LIN Sporadic Frame
function block are presented below:
Table 18. LIN Sporadic Frame Function Block Configuration Parameters
Name
Default
Value
Range
Units
Description
LIN Frame Kind
Undefined
{Undefined, Publish,
Subscribe}
–
Defines whether the frame
is transmitted or received.
Unconditional
Frame #1 Number
0
[0…25]
–
Number of the 1-st
LIN
Unconditional Frame
function block.
Unconditional
Frame #2 Number
0
[0…25]
–
Number of the 2-nd
LIN
Unconditional Frame
function block.
…
…
…
…
…
Unconditional
Frame #5 Number
0
[0…25]
–
Number of the 5-th
LIN
Unconditional Frame
function block.
Sending priorities in the sporadic frame are defined in the descending order: unconditional
frame #1 has the maximum priority and unconditional frame #5
– minimum. When
Unconditional Frame #1…5 Number
is equal to 0, the frame is undefined.
3.3.7 Main Schedule Table
There is one
Main Schedule Table
function block available to the user. It is used by the master
node by default and can contain up to 25 schedule entries. There are no signal inputs and
outputs in this function block.
Figure 12. Main Schedule Table Function Block
Configuration parameters of the
Main Schedule Table
function block are presented below:
Table 19. Main Schedule Table Function Block Configuration Parameters
Name
Default
Value
Range
Units
Description
Entry #1 Frame
Type
Undefined
{Undefined,
Unconditional, Event
Triggered, Sporadic}
–
1-st schedule entry frame
type.
Entry #1 Frame
Number
0
Depends on the frame
type
–
1-st schedule entry frame
number.
Entry #1 Delay
0
[0…10000]
ms
1-st schedule entry delay.
Main Schedule
Table
Schedule Entry 1
Schedule Entry 2
Schedule Entry 25
….