UMAX140610. LIN
– J1939 CAN Protocol Converter with PWM Output. Version 1
Page: 24-81
Name
Default
Value
Range
Units
Description
Associated with
Event Triggered
Frame
False
{False, True}
–
Defines whether this
Frame is used in the Event
Triggered Frame.
Size
1
[1…8]
byte
Frame Size.
Checksum Type
Classic
{Classic, Enhanced}
–
Type of the frame
checksum.
Signal #1 Number
0
[0…130]
–
Number of the 1-st
LIN
Signal
function block.
Signal #1 Offset
0
[0…63]
bit
Offset of the LIN signal
defined by the 1-st
LIN
Signal
function block.
Signal #2 Number
0
[0…130]
–
Number of the 2-nd
LIN
Signal
function block.
Signal #2 Offset
0
[0…63]
bit
Offset of the LIN signal
defined by the 2-nd
LIN
Signal
function block.
…
…
…
…
…
Signal #15 Number 0
[0…130]
–
Number of the 15-th
LIN
Signal
function block.
Signal #15 Offset
0
[0…63]
bit
Offset of the LIN signal
defined by the 15-th
LIN
Signal
function block.
The
LIN Signal
function blocks are numbered from 1 to 15. When the
Signal #1…15 Number
is
equal to 0, the
LIN Signal
function block is not defined and the associated
Signal #1…15
Offset
configuration parameter is not used.
3.3.5 LIN Event Triggered Frame
There is one
LIN Event Triggered Frame
function block available to the user. It can contain up
to 5 associated LIN frames. There are no signal inputs and outputs in this function block.
Figure 10. LIN Event Triggered Frame Function Block
Configuration parameters of the
LIN Event Triggered Frame
function block are presented
below:
LIN Event Triggered
Frame
Unconditional Frame 1
Unconditional Frame 2
Unconditional Frame 5
….