UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
30 - 141
9
2500h sub-index 7 (Extra Received PV 7)
10
2500h sub-index 8 (Extra Received PV 8)
11
2500h sub-index 9 (Extra Received PV 9)
12
2500h sub-index 10 (Extra Received PV 10)
13
2500h sub-index 11 (Extra Received PV 11)
14
2500h sub-index 12 (Extra Received PV 12)
15
2500h sub-index 13 (Extra Received PV 13)
16
2500h sub-index 14 (Extra Received PV 14)
Analog Input Function Block
1
7100h sub-index 1 or 6000h sub-index 1 bit 0
2
7100h sub-index 2 or 6000h sub-index 1 bit 1
Constant Function Block
1
5010h sub-index 1 (always FALSE)
2
5010h sub-index 2 (always TRUE)
3
5010h sub-index 3 (Constant FV 3)
4
5010h sub-index 4 (Constant FV 4)
5
5010h sub-index 5 (Constant FV 5)
6
5010h sub-index 6 (Constant FV 6)
7
5010h sub-index 7 (Constant FV 7)
8
5010h sub-index 8 (Constant FV 8)
9
5010h sub-index 9 (Constant FV 9)
10
5010h sub-index 10 (Constant FV 10)
11
5010h sub-index 11 (Constant FV 11)
12
5010h sub-index 12 (Constant FV 12)
13
5010h sub-index 13 (Constant FV 13)
14
5010h sub-index 14 (Constant FV 14)
15
5010h sub-index 15 (Constant FV 15)
PID Control Function Block
1
2460h sub-index 1 (PID Output FV 1)
2
2460h sub-index 2 (PID Output FV 2)
Lookup Table Function Block
1
3017h (Lookup Table 1 Output Y-Axis PV)
2
3027h (Lookup Table 2 Output Y-Axis PV)
3
3037h (Lookup Table 3 Output Y-Axis PV)
4
3047h (Lookup Table 4 Output Y-Axis PV)
5
3057h (Lookup Table 5 Output Y-Axis PV)
6
3067h (Lookup Table 6 Output Y-Axis PV)
7
3077h (Lookup Table 7 Output Y-Axis PV)
8
3087h (Lookup Table 8 Output Y-Axis PV)
Mathematical Function Block
1
4350h sub-index 1 (Math Output PV 1)
2
4350h sub-index 2 (Math Output PV 2)
3
4350h sub-index 3 (Math Output PV 3)
4
4350h sub-index 4 (Math Output PV 4)
Programmable Logic Function Block
1
3xy7h (Lookup Table Selected by Logic 1)
2
3xy7h (Lookup Table Selected by Logic 2)
3
3xy7h (Lookup Table Selected by Logic 3)
4
3xy7h (Lookup Table Selected by Logic 4)
Inching Function Block
1
2602h (Inching Field Value)
NOTE: The following options should be considered for diagnostic feedback, and should not be
selected as a control source for logic inputs (i.e. output control or lookup table X-Axis)
Output Commanded Field Value
1
7330h sub-index 1 or 6000h sub-index 1 bit 0
2
7330h sub-index 2 or 6000h sub-index 1 bit 1
Output Feedback Field Value
1
2370h sub-index 1 (UO1 FB)