UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
105 - 141
Object Description
Index
2381h
Name
AO Output Frequency PWM Amplitude
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Output Frequency PWM Amplitude
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (5V amplitude)
2.4.29. Object 2390h: AO Frequency Input Source
This object defines the type of input that will be used to control frequency of output in mixed output mode.
The available control sources on the 2IN-2OUT-SIG-CO controller are listed in Table 22. Not all sources would
make sense to control the AO, and it is the user’s responsibility to select a source that makes sense for the
application.
Object Description
Index
2360h
Name
AO Frequency Input Source
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Frequency Input Source
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (control not used)