UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
63 - 141
Sub-Index
2h
Description
Digital Input Error
Access
RW
PDO Mapping
No
Value Range
See above
Default Value
1 (No State Change)
Sub-Index
3h
Description
Analog Input Error
Access
RW
PDO Mapping
No
Value Range
See above
Default Value
1 (No State Change)
Sub-Index
4h
Description
Digital Output Error
Access
RW
PDO Mapping
No
Value Range
See above
Default Value
1 (No State Change)
Sub-Index
5h
Description
Analog Output Error
Access
RW
PDO Mapping
No
Value Range
See above
Default Value
1 (No State Change)
Sub-Index
6h
Description
Fault Detection Error
Access
RW
PDO Mapping
No
Value Range
See above
Default Value
0 (Pre-Operational)
2.2.14. RPDO Behavior
Per the CANopen ® standard DS-301, the following procedure shall be used for re-mapping, and is the same
for both RPDOs and TPDOs.
a) Destroy the PDO by setting bit
exists
(most significant bit)
of sub-index 01h of the according PDO
communication parameter to 1b
b) Disable mapping by setting sub-index 00h of the corresponding mapping object to 0
c) Modify the mapping by changing the values of the corresponding sub-indices
d) Enable mapping by setting sub-index 00h to the number of mapped objects
e) Create the PDO by setting bit
exists
(most significant bit) of sub-index 01h of the according PDO
communication parameter to 0b
The 2IN-2OUT-SIG-CO Controller can support up to six RPDO messages. All RPDOs on the 2IN-2OUT-SIG-
CO Controller use the similar default communication parameters, with the PDO IDs set according to the pre-