UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
119 - 141
This read-only object contains the lookup table function block PV that can be used as the input source for
another function block (i.e. analog output.) The physical unit for this object is undefined, and it will use the
resolution defined in object 3yz4h, LTz Y-Axis Decimal Digits PV.
Object Description
Index
3yz8h (where yz = 01 to 08)
Name
LTyz Output Y-Axis PV
Object Type
VARIABLE
Data Type
INTEGER16
Entry Description
Sub-Index
0h
Access
RO
PDO Mapping
Yes
Value Range
Integer16
Default Value
No
2.4.55. Object 3300h: Logic Block Enable
This object defines whether or not the logic shown in Figure 19 will be evaluated.
Object Description
Index
3300h
Name
Logic Block Enable
Object Type
ARRAY
Data Type
BOOLEAN
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (x = 1 to 4)
Description
LBx Enable
Access
RW
PDO Mapping
No
Value Range
0 (FALSE) or 1 (TRUE)
Default Value
0 [FALSE]
2.4.56. Object 3310h: Logic Block Selected Table