UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
62 - 141
Default Value
2
Sub-Index
1h
Description
Configuration date
Access
RO
PDO Mapping
No
Value Range
UNSIGNED32
Default Value
No
Sub-Index
2h
Description
Configuration time
Access
RO
PDO Mapping
No
Value Range
UNSIGNED32
Default Value
No
2.2.13. Object 1029h: Error Behavior
This object controls the state that the 2IN-2OUT-SIG-CO Controller will be set into in case of an error of the
type associated with the sub-index.
A network fault is flagged when an RPDO is not received within the expected time period defined in the “Event
Timer” of the associated communication objects, (see Section 2.2.14 for more information) or if a lifeguard or
heartbeat message is not received as expected. Input faults are defined in Section 1.1, and Power Supply
faults are described in Section 1.10.
For all sub-indexes, the following definitions hold true:
0 = Pre-Operational
(node reverts to a pre-operational state when this fault is detected)
1 = No State Change
(node remains in the same state it was in when the fault occurred)
2 = Stopped
(node goes into stopped mode when the fault occurs)
Object Description
Index
1029h
Name
Error Behaviour
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Number of entries
Access
RO
PDO Mapping
No
Value Range
0 to 6
Default Value
6
Sub-Index
1h
Description
Communication Fault
Access
RW
PDO Mapping
No
Value Range
See above
Default Value
0 (Pre-Operational)