UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
70 - 141
2.3.3. Object 7100h: AI Input Field Value
This object represents the measured value of an analog input that has been scaled as per manufacturer object
2102h AI Decimal Digits PV. The base unit for each type of input is defined in Table 4, as well as the read-
only resolution (decimal digits) associated with the FV.
Object Description
Index
7100h
Name
AI Input Field Value
Object Type
ARRAY
Data Type
INTEGER16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AIx Input Field Value
Access
RO
PDO Mapping
Yes
Value Range
Data Type Specific, see Table 5
Default Value
No
2.3.4. Object 6110h: AI Sensor Type
This object defines the type of sensor (input) which is connected to the analog input pin.
Object Description
Index
6110h
Name
AI Sensor Type
Object Type
ARRAY
Data Type
UNSIGNED16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
1
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AIx Sensor Type
Access
RW
PDO Mapping
No