Axetris AG
LGD F200P2 Operating Instructions - Rev D
19.09.2018
11/60
1.2 Technical Data
Environmental conditions
Parameter
Unit
Value / Range
Usage
-
Interior use
Maximum
operating
temperature range
C
F
15 …50 (H), -30 … 65 (A) (except CH
4
(A): -10 …65)
59 …122 (H), -22 … 149 (A) (except CH
4
(A): 14 …149)
Operating humidity
% r.H. 0 … 99, non-condensing
Operating pressure
mbar
800 … 1’100
Storage temperature
C
F
-40 … 80
-40 … 176
Storage humidity
% r.H. 0 … 99, non-condensing
Emission level L
pa
*
dB
<70
*specification for CE conformity
Mechanical characteristics
Parameter
Unit
Value / Range
Measurement cell
-
Flow-through setup
Standard cell length
mm
inches
200
7.9
Std. optical path length
mm
inches
400
15.7
Standard cell volume
mL
15
Maximum measurement gas
flow rate (Minimum)
mL /
min
5’000 (1’000)
Dimensions housing
mm
3
380 x 122 x 78 (heated version)
340 x 107 x 78 (ambient version)
Approx. weight
kg
3.3 (heated version)
1.9 (ambient version)
Inlet / outlet connectors,
measurement gas
mm
6 O.D., Swagelok
Inlet / outlet connectors, purge
gas (optional)
mm
6 O.D., push-in fitting (optional accessory)
Summary of Contents for LGD F200P2
Page 1: ...Operating Integration Instructions Laser Gas Detection OEM Module LGD F200P2 Axetris AG...
Page 57: ...Axetris AG LGD F200P2 Operating Instructions Rev D 19 09 2018 57 60 Notes...
Page 58: ...Axetris AG LGD F200P2 Operating Instructions Rev D 19 09 2018 58 60 Notes...
Page 59: ...Axetris AG LGD F200P2 Operating Instructions Rev D 19 09 2018 59 60 Notes...
Page 60: ...Axetris AG LGD F200P2 Operating Instructions Rev D 19 09 2018 60 60 Notes...