Jet Cleaner TANKO-MX
6 Commissioning
Operating/Installation Instructions 2019/08
47/102
6.3
Switch-on procedure
In accordance with the type of device activation and how it is integrated (e.g. manual or automatic) on
the cleaning plant, the switch-on procedure has to be integrated and the following instructions have to
be observed when switching on.
WARNING
Risk from sudden, unforeseeable or unauthorized activation of the device (e.g. triggering
of a start command as a result of incorrect operation of a start-up control device)!
For a safe cleaning process it is urgently necessary to consistently follow the sequence of
safety-relevant switching processes. Non-compliance prevents operational safety, thus
leading to hazards.
There is a risk of death or severe physical injury.
When commissioning the device, the switch-on procedure working steps must be
followed in the given order.
SWITCH-ON PROCEDURE
Work steps
1. Securely close all of the openings on the container (e.g. inspection openings).
2. Switch off all moving parts in the container (e.g. agitators) and secure them to
prevent them from being inadvertently switched back on or set in motion.
3. Open the outlet of the container for the cleaning medium.
Check whether the cleaning medium fed into the container can drain freely during
cleaning and does NOT collect together.
4. Switch on the cleaning medium supply (e.g. slowly open the shut-off valve or ball
cock).
Check that the supply of cleaning medium is NOT interrupted (e.g. flow meter) and
the media pressure on the device is established.
5. Take suitable measures to secure the supply of cleaning medium to prevent it from
switching off suddenly, unexpectedly or without authorization.