Jet Cleaner TANKO-MX
3 Construction and Function
Operating/Installation Instructions 2019/08
25/102
NOTE
Applications with fully demineralized water:
Ultra pure water, ultra pure water vapor and ultra pure water vapor condensate can have extremely
corrosive effects under certain conditions. Particularly with elevated operating temperatures
(e.g. 80 °C to 120 °C) and with increasing operating time, corrosion reactions are possible including
where stainless steel is used.
The appearance of corrosion on supposedly ‘rust-proof’ steels occurs in various classes or types and
depends on countless influencing parameters such as temperature, pressure, degree of mineralization
of the media (pH value and electrical conductivity) and operating time.
In practice, the special types of corrosion of rust-proof steels cannot always be prevented, but
can be significantly minimized and delayed.
If you have any questions or uncertainties about this, please consult AWH!