5.
Take the tensioning wire through the tensioning wire mounting blocks and the cover profile. Fasten
the tensioning wire mounting blocks in the clamping plate with M8x25 bolts. Note: Make sure the
mounting blocks are centered under the front profile.
6.
Keep at both sides of the mounting block and the cover profile a distance of 2 mm. Fasten the cover
profile through the holes of 6,5 mm.
7.
Fasten the hexagon connection nut with a washer to the side of the tensioning wire with screw-
thread. On the other side the clamping sleeve with wedge set is positioned.
8.
Turn the hexagon connection nut tight to tension the front profile straight.