74
ZQ375 Checkweigher User Instructions
Supervisor menu
l
Set the outputs to be latched or unlatched
l
Enable outputs on or off in gross zero band
l
Set the under and over segment division size
l
Turn weight digits on or off during checkweighing
l
Turn the bargraph on or off during checkweighing
l
Set the type of checkweighing: Limits or Sample
l
Reset all the checkweighing items to factory defaults.
Follow the steps below.
Outputs
Check
Outputs
2.
From
chEcK
, press
SELECT
…
outPutS
is displayed. There are two choices for outputs,
LAtch
and
unLAtch
(default). If you choose
LAtch
, this means that weights will
have to stabilize at or above the output value before the relay or
annunciator changes. If you choose
unLAtch
, the relay and annunciator
will change instantly as the weight swings above and below the output
value.
3.
From
outPutS
, press
SELECT
…
The current choice is displayed,
LAtch
or
unLAtch
.
4.
Press
or
UNITS
to toggle between the choices and when your choice is
displayed, press
ZERO
to accept …
outPutS
is displayed.
Output-gross zero band
Check
Outputs
Out-gzb
5.
Press
UNITS
to go to the next menu item …
out-gZb
is displayed. This stands for output-gross zero band. You can
set outputs to
on
(default) while the weight is in the gross zero band or
set them to
oFF
while the weight is in the gross zero band.
6.
Press
SELECT
…
The current choice is displayed.
7.
Press
or
UNITS
to toggle between the choices and when your choice is
displayed, press
ZERO
to accept …
out-gZb
is displayed.