68
ZQ375 Checkweigher User Instructions
Supervisor menu
Output-gross zero band
Check
Outputs
Out-gzb
5.
Press
UNITS
to go to the next menu item …
out-gZb
is displayed. This stands for output-gross zero band. You can
set outputs to
on
(default) while the weight is in the gross zero band or
set them to
oFF
while the weight is in the gross zero band.
6.
Press
SELECT
…
The current choice is displayed.
7.
Press
or
UNITS
to toggle between the choices and when your choice is
displayed, press
ZERO
to accept …
out-gZb
is displayed.
Under segment division
Check
Outputs
Out-gzb
USegDiv
8.
Press
UNITS
to go to the next menu item …
uSEgdiV
is displayed. This stands for under-segment division size.
Choose how many divisions are equal to one segment on the
UNDER
display bargraph. You can key in a value from 1 to 1000 divisions per
segment.
9.
Press
SELECT
…
The current value is displayed.
10.
Key in a new value and press
ZERO
to accept …
uSEgdiV
is displayed.
Over segment division
Check
Outputs
Out-gzb
USegDiv
OSegDiv
11.
Press
UNITS
to go to the next menu item …
oSEgdiV
is displayed. This stands for over-segment division size.
Choose how many divisions are equal to one segment on the
OVER
display bargraph. You can key in a value from 1 to 1000 divisions per
segment.
12.
Press
SELECT
…
The current value is displayed.
13.
Key in a new value and press
ZERO
to accept …
oSEgdiV
is displayed.
All numeric values require scroll entry. See
Numeric entry procedure on page 19
.