FLSC 05 w/FLI 225 Instrument Service Manual
89
10 Replacing Weigh Bars on the FLSC 05 Carriage
10.
Place the screws through the recessed holes, shown in Figure 10.5, to attach
the cable guards to the carriage back plate. Tighten the screws.
11.
Tighten the jam nuts to 50 ft pounds.
12.
Attach all Weigh Bar cables to the junction box as shown in Figure 10.14. The
top Weigh Bars are attached to the connectors closest to the front plate of the
scale carriage.
Figure 10.14 Weigh Bar cables attached to junction box.
13.
Attach the interface cable. Route the cable as shown in Figure 10.15. The
photo shows the exit path if the cable is exiting at the top center or on the right
side of the carriage. The drawn line shows the cable routing if you want the
cable exit on the left side of the carriage. Pay close attention that the cable is
routed between the Weigh Bar connectors and under the standoff.
Figure 10.15 Interface cable routing
14.
Attach the jbox retainer plate to the standoffs and tighten the two bolts.
15.
Place the scale carriage on the forklift, add the forks and pick up a loaded
pallet.
16.
With a helper, block the back of the forks with a wedge shaped piece of wood
while lowering the carriage so the scale will tilt forward when lowered.
17.
Lower the scale so that it disengages from the forklift carriage.
Top Weigh Bar connectors
Summary of Contents for FLI 225
Page 10: ...10 FLSC 05 w FLI 225 Instrument Service Manual ...
Page 11: ...FLSC 05 w FLI 225 Instrument Service Manual 11 1 FCC and EMC Declarations of compliance ...
Page 70: ...70 FLSC 05 w FLI 225 Instrument Service Manual Chart of ASCII Characters ...
Page 106: ...106 FLSC 05 w FLI 225 Instrument Service Manual 11 5 Exploded View of FLI 225 AWT05 500348 ...
Page 109: ......